Hunter RX lift will not lower and shows MISMATCHED LOCKS
What usually causes it
- The locks caught at different heights, so the lift turns off the lower button until it is levelled again
What we do
Keep everyone clear. If the message keeps coming back, our technician checks the locks and the levelling system on the rack and repairs the cause of the mismatch.